1LH SERIES 480V
Phase-Converting Variable Frequency Drives
1LH4xxR 60 - 125 HP
1LH Performance Series VFD’s are the only product on the market with optional AuxPower™, a revolutionary solid state phase converter integrated in the cabinet with the VFD.
Description
Summary
Phase Technologies has designed a groundbreaking VFD that provides full-featured speed control of the main pump and AuxPower™, an optional, independently controlled phase converter to power the entire center pivot system. Compared to a rotary phase converter, AuxPower™ provides superior voltage balance, greater efficiency and higher reliability. Reduce labor cost with one integrated panel that provides everything required for center pivot irrigation.
1LH Series drives have a unique active switching input module that does not produce high levels of harmonic distortion. These drives are IEEE 519 compliant with no additional harmonic filter required. The active front end also provides the added benefit of power conditioning for the VFD and AuxPower™ outputs. This allows the user to set the output voltage and control both the pump and pivot without concern for utility power fluctuations.
An optional Voltage doubling 1LH Series drive utilizes a single-phase active front end to boost the 208/240V input and generate 460V three-phase output. This innovative capability eliminates the cost of a transformer and provides significant cost reduction in submersible or long applications by reducing the size of down-hole motor cables. Phase Technologies now manufactures optional sine filters at a fraction of industry cost to further reduce expenses associated with long lead installations.
Industries served: Pivot Irrigation, Wells Pumps
Standard Features
- NEMA 3R Enclosure w/Insect Guards
- Easy Perfect Pressure™ Setup
- 2-Year Warranty
- 122° F (50° C) Rated
- Easy Field Serviceability
- IEEE 519 Compliant
Accessories
Optional Add-Ons
- AuxPower™ 18A or 32A
- MCCB & Service Rated Disconnect
- Dv/dt Output Filter (Integrated)
- Sine Wave output Filter (Integrated)
- HOA & Speed Potentiometer
- Strikesorb Surge Protection
- 0 - 150 psi Transducer
- Pad Mount Kit
Specifications
Models: | 1LH460R | 1LH475R | 1LH4100R | 1LH4125R |
General Power Specs | (not IEEE 519) | |||
Rated HP | 60 HP | 75 HP | 100 HP | 4125 HP |
Rated Input Current | 143A | 170A | 226A | 170A |
Input Current w/AuxPower™ C | 169A | 196A | 252A | N/A |
Input Current w/AuxPower™ X | 195A | 222A | N/A | N/A |
Input Voltage | 460/480V, single-phase | |||
Rated Output Current | 91A | 107A | 142A | 172A |
Output Voltage | 460/480V, three-phase | |||
Other Specs | ||||
Recommended Breaker Size | 200A | 250A | 300A | 400A |
Breaker Size w/AuxPower™ C | 250A | 250A | 400A | N/A |
Breaker Size w/AuxPower™ X | 250A | 400A | 400A | N/A |
Enclosure size (H x W x D) | 60 x 66 x 23" | 60 x 66 x 23" | 60 x 66 x 23" | 60 x 66 x 23" |
Shipping Weight | 502 lbs | 547 lbs | 594 lbs | 652 lbs |
Shipping Type | Freight | Freight | Freight | Freight |